System Overview
maxit Comfort Floor
| Main area of application |
|
- Combination of floor heating system with impact sound reduction properties
- Rooms with large windows, with nowhere to place a radiator
- Mainly in residential areas and office buildings
|
| System Description |
 |
|
Tout = Outdoor temperature Tair = Indoor temperature. Adjustable for each room separately with room thermostats. Tfloor = Surface temperature of the floor. Emits the heat to the air. Twater,in = Incoming water temperature. Start with the warm pipe at the perimeter wall. Twater, out = Returning water. Twater,in and Twater,out are regulated through Tout and Tair. |
| (1) |
Floor covering: |
Any kind of floor covering can be applied. But a floor covering with good heat distribution properties such as tiles or parquet/laminate is recommended. If tiles are selected, use KM Flex (normal setting) or KM Flex & Fix (fast setting) |
| (2) |
Surface slab: |
Cement-based Floor 4310 (layer thickness 25 – 50 mm),
Cement-based Floor 4350 (layer thickness 25 – 50mm) or Calcium sulphate-based Floor 4450 (layer thickness (35 – 70mm) |
| (3) |
Dividing layer: |
Floor 4940 Geotextile |
| (4/5) |
Heating plates: |
(4) Floor 4900 Railed plate. (1200/600/35mm) aluminium plates embedded in the EPS
(5) Floor 4901 Corner plate. (1200/600/20mm)
aluminium plates fully glued to the EPS Floor 4902 Adjustment plate (not visible in this picture).(1200/600/20mm) plain EPS plates |
| (6) |
Heating pipes: |
Water-borne heating pipes, Æ 16-17mm |
| (7) |
Soft strips: |
Floor 4960 |
| (8) |
Optional installation layer: |
EPS boards or maxit Lightweight screeds Floor 4515 or Floor 4519 |
| (9) |
Substrate: |
e.g. concrete | |
| Machinery & Equipment |
Floor 4310 – Bulk systems, small pumps
Floor 4350 – Bulk systems, small pumps
Floor 4450 – Bulk systems, small pumps
wobble tool |
|
|
 |